So i redid the entire test again 5 times with diffrent voltages and resistor values to see if i had a constant test result. I also brought some better measuring equipment from work ( a fluke 187 multimeter and a fluke 199 scope meter) They all came with similar results Fs 26,300 Fh 35,50 Fl 18,80 Vb 1,35 Fb 55,80 Vas 4,68 Qms 8,92 Qes 0,12 Qts 0,11
This is totally diffrent from what I got with a cheap multimeter and I'm assuming I have correct values now. Altho the QTS seems very small now, or am I mistaken ?
|
|